Powering Ventilation, Driving Progress — Ventilation mining fans and mining blowers for underground mines, tunnels, and industrial sites.
+86 18397234555
[email protected]
No. 001, Nanjiao Town Industrial Park, Zhoucun District, Zibo City, Shandong Province
Mon - Fri, 9am - 5pm
There are two main ways to calculate the airflow of a fan in an industrial plant or mine: by direct measurement of velocity and area, and by using fan curves together with system pressure measurements
A centrifugal fan is used when a ventilation or process system needs higher static pressure, stable airflow and robust performance in demanding conditions. Unlike axial fans, which are optimised for h
Fan airflow is measured by determining how fast air is moving through a known area and then converting that information into a volume flow rate. In industrial ventilation and mine air surveys, this is
When people ask about typical CFM values for fans, they want to know what airflow ranges are common for different sizes and applications. CFM (cubic feet per minute) is a measure of volume flow rate,
Fans are simple and economical ventilation devices, but they do have disadvantages and limitations that need to be understood when designing industrial or mining systems. Recognising these drawbacks h
Knowing how to calculate fan requirements is essential for designing reliable ventilation in industrial plants and mines. Instead of starting from a catalogue, you begin by defining what the fan must
The difference between a centrifugal blower and an axial blower lies in how they move air, the pressure they can generate and where they are used. Both are types of fans, but their internal geometry i
CFM in fan airflow stands for cubic feet per minute, a unit that describes the volume of air a fan moves per minute. It does not measure pressure or speed directly; instead, it tells you how much air
The formula for fan air power expresses how much useful power is carried by the moving air stream, before motor and mechanical losses are considered. In its simplest form, air power is the product of
Knowing how to calculate CFM flow is fundamental for selecting and checking fans in industrial and mining ventilation. The most practical method is based on the relationship Q = A × V, which says that
There is no simple rule that axial fans are quieter than centrifugal fans or vice versa. Noise depends on fan size, speed, blade design, system resistance and how the fan is installed and silenced. In
Air density is not the same as atmospheric pressure, although the two are closely related. Air density is the mass of air per unit volume, usually expressed in kg/m³. Atmospheric pressure is the force
At an elevation of around 4000 m above sea level, the atmospheric pressure is much lower than at sea level. While exact values depend on temperature and local weather, a typical estimate is in the ran
A good fan curve is more than just a line on a catalogue; it is a clear picture of how a fan behaves in real ventilation systems. From a design and operations perspective, a good fan curve is one that
Vibration noise in duct ventilation fans is a sign that the fan, ductwork or supports are moving more than they should. This can be caused by mechanical problems such as imbalance and misalignment, or
A ventilation tunnel is an underground passage constructed primarily to move air rather than to carry vehicles, ore, or passengers. It is used as part of a ventilation system to supply fresh air or re
To know whether a fan is truly powerful, you have to look beyond its physical size or motor nameplate and examine its airflow, pressure and power ratings at the duty point. A large fan that can only m
There is no single fixed price for an air tunnel, because the cost depends on many project-specific factors. When people ask how much an air tunnel or ventilation tunnel costs, they may be thinking ab
Learning how to study a fan curve is essential for anyone involved in selecting or troubleshooting ventilation fans in industrial plants and mines. A fan curve is a graphical summary of how a fan beha
Tunnel ventilation is important because it makes enclosed road, rail, metro and mining tunnels safe and usable. Without a designed ventilation system, exhaust gases, dust, heat and smoke would quickly
Fan curve theory describes how a fan behaves when it is connected to a real ventilation system. Instead of having a single fixed output, every fan has a whole range of possible combinations of airflow
An air tunnel is an underground passage or structure built mainly to move air rather than to carry vehicles or ore. It works by providing a low-resistance path that allows pressure differences, create
A fan curve is one of the most useful tools in ventilation engineering because it tells you, at a glance, how a fan will behave when installed in a real system. Instead of giving only a single rating,
The fan blade shape that moves more air most efficiently is usually an airfoil profile, but the best blade shape for a ventilation system depends on pressure, dust, noise and cost requirements. In ind
Tunnels have exhaust fans because enclosed underground spaces cannot rely on natural airflow alone to keep air safe and clear. Exhaust fans are a key part of tunnel ventilation systems. They remove po
Whether it is better to have your fan higher or lower depends on what you are trying to achieve with the ventilation system. Fan height and position strongly influence how air moves through a room, in
The difference between cross ventilation and tunnel ventilation lies in the direction of airflow and how it is generated. Cross ventilation is typically a natural or low-pressure airflow moving across
Knowing how to set up proper fan curves is essential for reliable engineering of industrial and mining ventilation systems. A proper fan curve is not drawn by guesswork; it is based on tested performa
A duct booster fan typically lasts around 5 to 10 years in normal residential or light industrial use, although actual life can be shorter or longer depending on quality, operating time and maintenanc
A tunnel ventilation system is the complete combination of equipment and controls used to manage airflow, air quality and smoke in road, rail, metro and mining tunnels. It includes main supply and exh
Our engineers are ready to provide custom calculations and solutions for your project.
Method 1: Scan the QR code to add
Method 2: Copy the WeChat ID and add manually
BofengFans