Powering Ventilation, Driving Progress — Ventilation mining fans and mining blowers for underground mines, tunnels, and industrial sites.
+86 18397234555
[email protected]
No. 001, Nanjiao Town Industrial Park, Zhoucun District, Zibo City, Shandong Province
Mon - Fri, 9am - 5pm
Recognising the signs of poor air ventilation is essential for maintaining safe and comfortable conditions in buildings, factories and underground mines. Many problems show up first as simple discomfo
The key difference between a centrifugal fan and an axial fan is the direction in which air leaves the impeller and the pressure each type can develop. This has a direct impact on where each fan is us
The question “How much does a ventilation system cost?” does not have a single answer, because ventilation systems range from small workshop exhaust setups to multi-level industrial plants and complex
An auxiliary fan is a secondary ventilation fan used to provide local airflow in specific areas where the main fan cannot deliver enough fresh air on its own. It does not replace the main ventilation
When people talk about the five types of ventilation, they are usually grouping different ways of moving air into and out of buildings, factories and underground mines. The names vary between standard
You should stop using a fan whenever its continued operation could damage equipment or compromise safety. For household fans this is simple, but for industrial and mining fans the decision involves te
The short answer to “How much does a ventilation fan cost?” is that it depends strongly on the size, duty and environment. A small light-duty unit for a workshop may cost only a modest amount, while a
The system of auxiliary ventilation is the collection of fans, ducts and controls that provides local ventilation to areas not adequately served by the main ventilation circuit. It is most commonly di
Calculating fan pressure means determining how much pressure the fan adds to the air as it passes through the machine. This value is fundamental for matching a fan to a duct system, mine airway or pro
Choosing what size ventilation fan you need is not just a matter of guessing or buying the largest model you can afford. Proper sizing is based on required airflow, system pressure and operating condi
To calculate the airflow of a fan, you need both a basic volume flow formula and an understanding of where the fan operates on its performance curve. In industrial plants and mines, airflow is usually
Asking which is better, a ventilation fan or an exhaust fan can be misleading, because the two terms describe different roles in the same system. An exhaust fan is a specific type of ventilation fan t
CFM stands for cubic feet per minute, and the basic formula for calculating CFM is very simple: CFM = Velocity (ft/min) × Area (ft²) This relationship comes from the definition of volume flow: the am
In many cases you can use a ventilation fan as an exhaust fan, but only if the fan and system are suited to that role. The term “ventilation fan” simply means a fan used to move air for ventilation; i
Fan efficiency tells you how effectively a fan converts shaft power from the motor into useful air power in the system. High efficiency is important in industrial plants and mines because ventilation
When people ask which form of ventilation is best, they usually hope for a single simple answer. In practice, there is no one system that is always best for every situation. The most suitable form of
The core formula for airflow is very simple and widely used in ventilation engineering: Q = V × A where Q is the volume flow rate, V is the average air velocity and A is the cross sectional area throu
Knowing how to choose a ventilation fan is essential for anyone responsible for air quality in a building, factory, tunnel or mine. A fan that is too small, the wrong type or made from unsuitable mate
Calculating ventilation requirements means determining how much fresh air you must supply and exhaust to control heat, contaminants and air quality. In industrial plants and mines, this is a critical
Yes, an exhaust fan can remove hot air, and this is one of its most common and useful functions in buildings, industrial plants and underground mines. By extracting hot air from a space and dischargin
CFM stands for “cubic feet per minute” and it is the basic unit used to describe how much air a fan moves every minute. When you see a fan rated at 5,000 CFM or 60,000 CFM, this number tells you the v
When asking about the price of an 8000 CFM exhaust fan, it is important to understand that 8000 CFM only describes airflow, not the full specification of the fan. The actual price can vary widely depe
Fan airflow pressure is measured by comparing air pressure at the fan inlet and outlet using suitable instruments and defined test points. In industrial and mining ventilation, understanding this pres
The cost of a ventilation system is more than just the price of a few fans. It is the total investment needed to move air safely and efficiently through a building, industrial plant, tunnel or mine. T
Calculating air pressure in a ventilation system means determining how much pressure exists at different points and how much is lost as air flows through ducts or mine airways. This information is ess
There is no single fixed price for an air ventilation system, because every project has different airflow, pressure and safety requirements. A small workshop might only need a simple exhaust system wi
There is no single “good” airflow value that fits every fan, because the right airflow depends on what you are trying to ventilate and why. A small office, a welding booth, a kiln and an underground h
The difference between a ventilation fan and an exhaust fan is mainly about how we use the words. A ventilation fan is a general term for any fan that moves air as part of a ventilation system. It may
Calculating CFM with pressure means using measured pressure values together with fan performance data or duct equations to work out the airflow. This approach is common in industrial and mining ventil
For most industrial plants, commercial buildings and underground mines, a ventilation system is absolutely worth the cost. In many cases it is not just desirable but legally required. A properly desig
Our engineers are ready to provide custom calculations and solutions for your project.
Method 1: Scan the QR code to add
Method 2: Copy the WeChat ID and add manually
BofengFans
Open WeChat > top-right “+” > Add Contacts > paste the WeChat ID, or scan the QR code above.