Powering Ventilation, Driving Progress — Ventilation mining fans and mining blowers for underground mines, tunnels, and industrial sites.
+86 18397234555
[email protected]
No. 001, Nanjiao Town Industrial Park, Zhoucun District, Zibo City, Shandong Province
Mon - Fri, 9am - 5pm
Knowing how to maximize airflow with a fan is essential for getting the most out of your ventilation system. Whether you are dealing with a workshop, an industrial plant or an underground mine, the ai
Vibration or wobble in industrial ventilation fans is a warning sign that should never be ignored. In mining and plant ventilation systems, excessive vibration can damage equipment, shorten bearing li
“Mine fans” is a broad term that covers several fan categories used to move air through underground mines, surface facilities, and associated tunnels. The most practical way to classify mine fans is b
When people ask what style of fan moves the most air, they are usually thinking about total volume of air moved, or how strongly the airflow is felt in a room or tunnel. The answer depends on the envi
Centrifugal fans are not automatically better than axial fans, and axial fans are not automatically better than centrifugal fans. Each type has advantages and limitations, so the best choice depends o
A booster fan in mining is a fan installed within the underground ventilation circuit to provide additional pressure and airflow to a specific district, panel, or branch of the mine. While the main fa
The static pressure curve of a fan is part of the fan performance chart that shows how static pressure varies with airflow at a given speed. It is one of the key tools engineers use to select and appl
An axial fan in mining is a ventilation fan that moves air primarily parallel to the fan’s axis, similar to how a propeller pushes air straight through. Axial fans are widely used in mining because th
When people ask how many types of fans are available, they are usually surprised by how many variations exist beyond simple household fans. In engineering practice, especially for industrial and minin
Higher static pressure is not automatically better for fans. What matters is that the fan can deliver the required airflow at the static pressure demanded by the system. Extra pressure beyond what the
In mining, a fan cut refers to a reduction in ventilation airflow caused by stopping a fan, slowing it down, changing its operating condition, or otherwise reducing the pressure that drives air throug
When someone points at a massive unit on a ceiling or at the mouth of a tunnel and asks, “What are those huge fans called?”, the answer depends on the setting. In large buildings and warehouses, they
You do not choose high or low static pressure in isolation; the “right” static pressure is the value your ventilation system actually needs at the required airflow. A well designed fan selection match
Mines use several kinds of ventilation fans, and the “right” fan depends on where it is used (main system vs local ventilation) and the required duty point (airflow and pressure). In most underground
Asking which fan type is best is a bit like asking which vehicle is best—truck, car or bus. The answer depends entirely on what you are trying to do. In ventilation engineering, the main fan types are
To plot a fan curve you need measured or manufacturer data showing how airflow, pressure and power change at different operating points for a given fan speed. From these data you graph pressure versus
Ventilation requirements in underground mines are fundamentally about providing enough fresh air to keep people safe and enable production while controlling airborne hazards. Although exact numeric re
The static pressure of a ventilation fan is the pressure the fan can develop to overcome system resistance at a particular airflow. It is not a single fixed number for the fan; instead, it varies alon
Mine ventilation fans can be grouped in two useful ways: by their function in the ventilation system (main, booster, auxiliary) and by aerodynamic design (axial or centrifugal). Both classifications m
A high velocity fan is generally understood to be a fan that produces a concentrated air stream with a relatively high outlet speed, rather than a gentle, broadly distributed flow. Instead of just mov
The PQ curve of a fan is the graph that shows the relationship between pressure (P) and airflow (Q) for that fan at a given speed. It is the core part of the fan performance chart and is essential for
An auxiliary fan in underground mines is a local ventilation fan used to move air in areas where the main ventilation circuit cannot supply enough airflow or cannot direct air effectively to the worki
Fast fan speed is a relative term that depends on the size and design of the fan. A small computer fan running at 3,000 rpm is normal, while a large mine ventilation fan running at the same rpm would
To increase fan airflow, you must either reduce the resistance of the system, increase the fan’s energy input or select a more suitable fan for the duty. In industrial plants and mines, the safest and
To ventilate a mine effectively, you need more than a fan. Mine ventilation is a controlled system that delivers fresh air to working areas, removes contaminated air through returns, and maintains sta
A vortex fan is a fan or blower designed to create a spiralling, vortex-like airflow rather than a simple straight jet. By shaping the housing and blades, the fan induces rotation in the air stream, f
In building, industrial and mining applications, mechanical ventilation can be described in four practical stages: intake, treatment, distribution and exhaust. Seeing the system as these stages helps
Miners need ventilation because underground environments do not naturally provide safe, breathable air at the scale required for modern mining. Ventilation is the primary engineering control that supp
The three fan laws, also known as the fan affinity laws, describe how airflow, pressure and power change when the speed or size of a geometrically similar fan is altered. These simple relationships ar
The cost to repair an industrial ventilation fan can vary widely, from a few hundred to several thousand dollars or more. The final price depends on fan size, what has failed, the cost of parts, labou
Our engineers are ready to provide custom calculations and solutions for your project.
Method 1: Scan the QR code to add
Method 2: Copy the WeChat ID and add manually
BofengFans